10 1 VGC VERSION 8 0 C YYYYMMDD VGC VERSION 19960423 20 1 VGC TSTSPON1 40 0 C TEST SPONSOR 30 1 VGC TSTSPON2 40 0 C TEST SPONSOR 2 40 1 VGC LABVALID 1 0 C V, I OR N TEST LAB VALIDATION (V, I OR N) 50 1 VGC INSTRUID 13 0 C INSTRUMENT ID 60 1 VGC INSTRUNO 5 0 C INSTRUMENT RUN NUMBER 70 1 VGC DTCOMP 8 0 C YYYYMMDD DATE COMPLETED (YYYYMMDD) 80 1 VGC EOTTIME 5 0 C HH:MM TIME COMPLETED (HH:MM) 90 1 VGC OILCODE 38 0 C OIL CODE 100 1 VGC CMIR 6 0 C CMIR 110 1 VGC ALTCODE1 10 0 C ALTERNATE OIL CODE 1 120 1 VGC ALTCODE2 10 0 C ALTERNATE OIL CODE 2 130 1 VGC ALTCODE3 10 0 C ALTERNATE OIL CODE 3 140 1 VGC OPVALID 8 0 C OPERATIONAL VALIDITY -- HAS/HAS NOT 150 1 VGC SUBLAB 40 0 C TESTING LABORATORY NAME 160 1 VGC SUBSIGIM 70 0 C TESTING LABORATORY VALIDATORS SIGNATURE 170 1 VGC SUBNAME 40 0 C TESTING LABORATORY VALIDATORS NAME 180 1 VGC SUBTITLE 40 0 C TESTING LABORATORY VALIDATORS TITLE 190 2 VGC LAB 2 0 C LAB CODE 200 2 VGC TSTMETH 25 0 C TEST METHOD 210 2 VGC MANUFACT 15 0 C MANUFACTURER 220 2 VGC MODEL 15 0 C MODEL 230 2 VGC IND 6 0 C TMC OIL CODE 240 2 VGC DTLSTCAL 8 0 C YYYYMMDD DATE OF LAST TMC CALIBRATION (YYYYMMDD) 250 2 VGC CALOILID 5 0 C CALIBRATION OIL ID 260 2 VGC DTCAL 8 0 C YYYYMMDD CALIBRATION DATE (YYYYMMDD) 270 2 VGC CALVOL 6 2 N CALIBRATION OIL % VOLATIZED @ 371'C... 700'F 280 2 VGC IONCOL 1 0 C Y OR N INJECTOR ON-COLUMN? (Y OR N) 290 2 VGC CARTYPE 2 0 C H, He, N CARRIER GAS TYPE (H, He, N) 300 2 VGC TMPPRO 1 0 C Y OR N TEMPERATURE PROGRAMMED? (Y OR N) 310 2 VGC CFLWRTE 5 1 N ml/min CARRIER GAS FLOW RATE (ml/min) 320 2 VGC TYPECOL 6 0 C TYPE OF COLUMN, PACKED OR OPEN 330 2 VGC SUPMAT 20 0 C PACKED COLUMN SUPPORT MATERIAL 340 2 VGC STAPHPAK 20 0 C PACKED COLUMN STATIONARY PHASE MATERIAL 350 2 VGC STAPHOPN 20 0 C OPEN COLUMN STATIONARY PHASE MATERIAL 360 2 VGC PERLOAD 6 2 N PACKED COLUMN PERCENT LOADING 370 2 VGC FILMTH 6 2 N ul OPEN COLUMN FILM THICKNESS (ul) 380 2 VGC COLTHPAK 5 1 N meters PACKED COLUMN LENGTH (meters) 390 2 VGC COLTHOPN 5 1 N meters OPEN COLUMN LENGTH (meters) 400 2 VGC COLDIAMP 5 2 N mm PACKED COLUMN DIAMETER (mm) 410 2 VGC COLDIAMO 5 2 N mm OPEN COLUMN DIAMETER (mm) 420 2 VGC RESOLPAK 5 1 N PACKED COLUMN RESOLUTION 430 2 VGC RESOLOPN 5 1 N OPEN COLUMN RESOLUTION 440 2 VGC INITMP 6 1 N øC TEMPERATURE PROGRAM INITIAL TEMPERATURE (øC ) 450 2 VGC SWGHT 8 4 N g SAMPLE WEIGHT (G) 460 2 VGC INIHLDTM 3 0 N min TEMPERATURE PROGRAM INITIAL HOLD TIME (MIN) 470 2 VGC SISTDWT 8 4 N g SAMPLE INTERNAL STANDARD WEIGHT (G) 480 2 VGC TMPRAMP 5 1 N øC /min TEMPERATURE PROGRAM TEMPERATURE RAMP (øC /MIN) 490 2 VGC TMPOVTCK 1 0 C Y OR N TEMPERATURE OVEN TRACK (Y OR N) 500 2 VGC VOLSI 4 1 N ul SAMPLE INJECTION VOLUME (UL) 510 2 VGC TMPFNL 6 1 N øC TEMPERATURE PROGRAM FINAL TEMPERATURE (øC ) 520 2 VGC SOLSI 20 0 C SAMPLE INJECTION SOLVENT 530 2 VGC HLDTMFNL 3 0 N min TEMPERATURE PROGRAM FINAL HOLD TIME (MIN) 540 2 VGC SCONSI 6 2 N % SAMPLE INJECTION SAMPLE CONCENTRATION (%) 550 2 VGC AUTOSI 1 0 C Y OR N SAMPLE INJECTION AUTOSAMPLER ? (Y OR N) 560 2 VGC DETYPE 20 0 C DETECTOR TYPE 570 2 VGC COMPROD 1 0 C Y OR N SOFTWARE COMMERCIAL PRODUCT ? (Y OR N) 580 2 VGC TMPDET 6 1 N øC DETECTOR TEMPERATURE (øC ) 590 2 VGC COMNAME 20 0 C SOFTWARE NAME OF COMMERCIAL PRODUCT 600 2 VGC RELRRxxx 5 2 N DETECTOR RELATIVE RESPONSE XXX 610 2 VGC SAMPVOL 6 2 N SAMPLE % VOLATIZED @ 371'C ... 700'F 620 3 VGC TOTCOM 2 0 Z TOTAL LINES OF COMMENTS & OUTLIERS 630 3 VGC OCOMHxxx 70 0 C OTHER DOWNTIME COMMENT XXX