########################################################################### # # # D a t a D i c t i o n a r y R e p e a t i n g # # F i e l d S p e c i f i c a t i o n s # # # ########################################################################### # The following contains specifications and field groupings for fields in the # Data Dictionary that are REPEATING Fields. These fields can be identified # in the Data Dictionary by the Hxxx or Rxxx in the last four positions of the # field name. # # Repeating fields are used to specify repeating measurements. # # The format for a repeating field name is 4 descriptive characters followed # by the letter H or R followed by 3 characters for the actual interval # the measurement was taken. The field will always be a total of 8 characters. # # Example ABCDHxxx. # # The following is the format of this specification: # # Column 1 - 8: Repeating Field Name # Column 10 - 17: The Parent Field Name of the Group # Column 19 - 26: The Measurement Interval Group Name # Column 30 - 80: Comments about the Repeating Field Group. # # The lines following the Repeating Field Name Record will contain the required # measurements for the particular field. Multiple 80 characters lines # can be specified. A blank line marks the end of each specification. # # The Field Name in Column 10-17 designates the the Group in which the field # belongs. The First field name in a group is the Parent of the grouping # and can be used to determine how fields should be grouped. # The changing of the Parent Field marks the end of a repeating group # specification. # # Example: # # VIS_Hxxx, DVISHxxx and PVISHxxx expanded for transmission (8 and 16 hours): # # VIS_H008 # DVISH008 # PVISH008 # VIS_H016 # DVISH016 # PVISH016 # # Note: During electronic transmission, repeating field groups must be kept # together within the specified group but the order within the group # does not have to be maintained. # ########################################################################### # Start of Field Grouping Specifications # ########################################################################### # T9 VERSION 20040727 TST_Hxxx TST_HXXX TST_HXXX TEST HOURS 025 050 075 752 100 150 200 250 300 350 400 425 450 475 500 TGA_Hxxx TST_Hxxx TST_Hxxx TGA PERCENT SOOT AT XXX HOURS 025 050 075 752 100 150 200 250 300 350 400 450 500 V100Hxxx TST_Hxxx TST_Hxxx VISCOSITY AT 100 DEG C AT XXX HOURS 025 050 075 100 150 200 250 300 350 400 450 500 IVISHxxx TST_Hxxx TST_Hxxx VISCOSITY INCREASE AT XXX HOURS 025 050 075 100 150 200 250 300 350 400 450 500 TBN4Hxxx TST_Hxxx TST_Hxxx TBN AT XXX HOURS 025 050 075 100 150 200 250 300 350 400 450 TBN2Hxxx TST_Hxxx TST_Hxxx TBN D2896 AT XXX HOURS 025 050 075 100 150 200 250 300 350 400 450 500 TAN_Hxxx TST_Hxxx TST_Hxxx TAN AT XXX HOURS 025 050 075 100 150 200 250 300 350 400 450 500 FEWMHxxx TST_Hxxx TST_Hxxx FE - WEAR METALS AT XXX HOURS [<] 025 050 075 100 150 200 250 300 350 400 450 500 PBWMHxxx TST_Hxxx TST_Hxxx PB - WEAR METALS AT XXX HOURS [<] 025 050 075 100 150 200 250 300 350 400 425 450 475 500 CUWMHxxx TST_Hxxx TST_Hxxx CU - WEAR METALS AT XXX HOURS [<] 025 050 075 100 150 200 250 300 350 400 450 500 CRWMHxxx TST_Hxxx TST_Hxxx CR - WEAR METALS AT XXX HOURS [<] 025 050 075 100 150 200 250 300 350 400 450 500 ALWMHxxx TST_Hxxx TST_Hxxx AL - WEAR METALS AT XXX HOURS [<] 025 050 075 100 150 200 250 300 350 400 450 500 SIWMHxxx TST_Hxxx TST_Hxxx SI - WEAR METALS AT XXX HOURS [<] 025 050 075 100 150 200 250 300 350 400 450 500 SNWMHxxx TST_Hxxx TST_Hxxx SN - WEAR METALS AT XXX HOURS [<] 025 050 075 100 150 200 250 300 350 400 450 500 NAWMHxxx TST_Hxxx TST_Hxxx NA - WEAR METALS AT XXX HOURS [<] 025 050 075 100 150 200 250 300 350 400 450 500 DOWNRxxx DOWNRxxx DOWNRxxx DOWNTIME TEST HOURS DDATRxxx DOWNRxxx DOWNRxxx DOWNTIME DATE DTIMRxxx DOWNRxxx DOWNRxxx DOWNTIME TIME DREARxxx DOWNRxxx DOWNRxxx DOWNTIME REASON OCOMRxxx OCOMRxxx OCOMRxxx OTHER DOWNTIME COMMENT XXX SITHRxxx SITHRxxx SITHRxxx STATIC INJECTION TIMING HOURS SIT_Rxxx SITHRxxx SITHRxxx STATIC INJECTION PUMP TIMING