########################################################################### # # # D a t a D i c t i o n a r y R e p e a t i n g # # F i e l d S p e c i f i c a t i o n s # # # ########################################################################### # The following contains specifications and field groupings for fields in the # Data Dictionary that are REPEATING Fields. These fields can be identified # in the Data Dictionary by the Hxxx or Rxxx in the last four positions of the # field name. # # Repeating fields are used to specify repeating measurements. # # The format for a repeating field name is 4 descriptive characters followed # by the letter H or R followed by 3 characters for the actual interval # the measurement was taken. The field will always be a total of 8 characters. # # Example ABCDHxxx. # # The following is the format of this specification: # # Column 1 - 8: Repeating Field Name # Column 10 - 17: The Parent Field Name of the Group # Column 19 - 80: Comments about the Repeating Field Group. # # The lines following the Repeating Field Name Record will contain the required # measurements for the particular field. Multiple 80 characters lines # can be specified. A blank line marks the end of each specification. # # The Field Name in Column 10-17 designates the the Group in which the field # belongs. The First field name in a group is the Parent of the grouping # and can be used to determine how fields should be grouped. # The changing of the Parent Field marks the end of a repeating group # specification. # # Example: # # VIS_Hxxx, DVISHxxx and PVISHxxx expanded for transmission (8 and 16 hours): # # VIS_H008 # DVISH008 # PVISH008 # VIS_H016 # DVISH016 # PVISH016 # # Note: During electronic transmission, repeating field groups must be kept # together with in the specified group but the order with in the group # does not have to be maintained. # ########################################################################### # Start of Field Grouping Specifications # ########################################################################### # T9 VERSION 19980804 TST_Hxxx TST_HXXX TEST HOURS (HHH) NEW 025 050 075 752 100 150 200 250 300 350 400 425 450 475 500 TGA_Hxxx TST_Hxxx TGA PERCENT SOOT AT XXX HOURS (%) NEW 025 050 075 752 100 150 200 250 300 350 400 450 500 V100Hxxx TST_Hxxx VISCOSITY AT 100 DEG C AT XXX HOURS (cSt) NEW 025 050 075 100 150 200 250 300 350 400 450 500 IVISHxxx TST_Hxxx VISCOSITY INCREASE AT XXX HOURS (cSt) 025 050 075 100 150 200 250 300 350 400 450 500 TBN4Hxxx TST_Hxxx TBN AT XXX HOURS NEW 025 050 075 100 150 200 250 300 350 400 450 TBN2Hxxx TST_Hxxx TBN D2896 AT XXX HOURS NEW 025 050 075 100 150 200 250 300 350 400 450 500 TAN_Hxxx TST_Hxxx TAN AT XXX HOURS NEW 025 050 075 100 150 200 250 300 350 400 450 500 FEWMHxxx TST_Hxxx FE - WEAR METALS AT XXX HOURS [<] (ppm) NEW 025 050 075 100 150 200 250 300 350 400 450 500 PBWMHxxx TST_Hxxx PB - WEAR METALS AT XXX HOURS [<] (ppm) NEW 025 050 075 100 150 200 250 300 350 400 425 450 475 500 CUWMHxxx TST_Hxxx CU - WEAR METALS AT XXX HOURS [<] (ppm) NEW 025 050 075 100 150 200 250 300 350 400 450 500 CRWMHxxx TST_Hxxx CR - WEAR METALS AT XXX HOURS [<] (ppm) NEW 025 050 075 100 150 200 250 300 350 400 450 500 ALWMHxxx TST_Hxxx AL - WEAR METALS AT XXX HOURS [<] (ppm) NEW 025 050 075 100 150 200 250 300 350 400 450 500 SIWMHxxx TST_Hxxx SI - WEAR METALS AT XXX HOURS [<] (ppm) NEW 025 050 075 100 150 200 250 300 350 400 450 500 SNWMHxxx TST_Hxxx SN - WEAR METALS AT XXX HOURS [<] (ppm) NEW 025 050 075 100 150 200 250 300 350 400 450 500 NAWMHxxx TST_Hxxx NA - WEAR METALS AT XXX HOURS [<] (ppm) NEW 025 050 075 100 150 200 250 300 350 400 450 500 DOWNHxxx DOWNHxxx DOWNTIME TEST HOURS (HHH:MM) DDATHxxx DOWNHxxx DOWNTIME DATE (YYYYMMDD) DTIMHxxx DOWNHxxx DOWNTIME TIME (HHH:MM) DREAHxxx DOWNHxxx DOWNTIME REASON OCOMHxxx OCOMHxxx OTHER DOWNTIME COMMENT XXX SITHHxxx SITHHxxx STATIC INJECTION TIMING HOURS (HH) SIT_Hxxx SITHHxxx STATIC INJECTION PUMP TIMING (DEG)