########################################################################### # # # D a t a D i c t i o n a r y R e p e a t i n g # # F i e l d S p e c i f i c a t i o n s # # # ########################################################################### # The following contains specifications and field groupings for fields in the # Data Dictionary that are REPEATING Fields. These fields can be identified # in the Data Dictionary by the Hxxx or Rxxx in the last four positions of the # field name. # # Repeating fields are used to specify repeating measurements. # # The format for a repeating field name is 4 descriptive characters followed # by the letter H or R followed by 3 characters for the actual interval # the measurement was taken. The field will always be a total of 8 characters. # # Example ABCDHxxx. # # The following is the format of this specification: # # Column 1 - 8: Repeating Field Name # Column 10 - 17: The Parent Field Name of the Group # Column 19 - 80: Comments about the Repeating Field Group. # # The lines following the Repeating Field Name Record will contain the required # measurements for the particular field. Multiple 80 characters lines # can be specified. A blank line marks the end of each specification. # # The Field Name in Column 10-17 designates the the Group in which the field # belongs. The First field name in a group is the Parent of the grouping # and can be used to determine how fields should be grouped. # The changing of the Parent Field marks the end of a repeating group # specification. # # Example: # # VIS_Hxxx, DVISHxxx and PVISHxxx expanded for transmission (8 and 16 hours): # # VIS_H008 # DVISH008 # PVISH008 # VIS_H016 # DVISH016 # PVISH016 # # Note: During electronic transmission, repeating field groups must be kept # together with in the specified group but the order with in the group # does not have to be maintained. # ########################################################################### # Start of Field Grouping Specifications # ########################################################################### # T8 VERSION 19980902 RVISHxxx RVISHxxx REFERENCE VISCOSITY AT 100 DEG C AT XXX TEST HOURS (cSt) NEW 025 050 075 100 125 150 175 200 225 275 300 DVISHxxx DVISHxxx REFERENCE VISCOSITY INCREASE AT XXX HOURS (cSt) 025 050 075 100 125 150 175 200 225 275 300 VIS_Hxxx VIS_Hxxx VISCOSITY AT 100 DEG C AT XXX HOURS (cSt) NEW 025 050 075 100 125 150 175 200 225 275 300 IVISHxxx IVISHxxx VISCOSITY INCREASE AT XXX HOURS (cSt) 025 050 075 100 125 150 175 200 225 275 300 RTGAHxxx RTGAHxxx TGA SOOT % AT XXX HOURS (%) NEW 025 050 075 100 125 150 175 200 225 275 300 TGA_Hxxx TGA_Hxxx TGA PERCENT SOOT AT XXX HOURS (%) NEW 025 050 075 100 125 150 175 200 225 275 300 FE__Hxxx FE__Hxxx IRON HOURS [<](ppm) NEW 150 250 300 PB__Hxxx PB__Hxxx LEAD HOURS [<](ppm) NEW 150 250 300 CU__Hxxx CU__Hxxx COPPER HOURS [<](ppm) NEW 150 250 300 CR__Hxxx CR__Hxxx CHROMIUM HOURS [<](ppm) NEW 150 250 300 AL__Hxxx AL__Hxxx ALUMINUM HOURS [<](ppm) NEW 150 250 300 SI__Hxxx SI__Hxxx SILICON HOURS [<](ppm) NEW 150 250 300 NA__Hxxx NA__Hxxx SODIUM HOURS [<](ppm) NEW 150 250 300 DOWNHxxx DOWNHxxx DOWNTIME TEST HOURS (HHH:MM) DDATHxxx DOWNHxxx DOWNTIME DATE (YYYYMMDD) DTIMHxxx DOWNHxxx DOWNTIME TIME (HHH:MM) DREAHxxx DOWNHxxx DOWNTIME REASON OCOMHxxx OCOMHxxx OTHER DOWNTINE COMMENT XXX