########################################################################### # # # D a t a D i c t i o n a r y R e p e a t i n g # # F i e l d S p e c i f i c a t i o n s # # # ########################################################################### # The following contains specifications and field groupings for fields in the # Data Dictionary that are REPEATING Fields. These fields can be identified # in the Data Dictionary by the Hxxx or Rxxx in the last four positions of the # field name. # # Repeating fields are used to specify repeating measurements. # # The format for a repeating field name is 4 descriptive characters followed # by the letter H or R followed by 3 characters for the actual interval # the measurement was taken. The field will always be a total of 8 characters. # # Example ABCDHxxx. # # The following is the format of this specification: # # Column 1 - 8: Repeating Field Name # Column 10 - 17: The Parent Field Name of the Group # Column 19 - 26: The Measurement Interval Group Name # Column 30 - 80: Comments about the Repeating Field Group. # # The lines following the Repeating Field Name Record will contain the required # measurements for the particular field. Multiple 80 characters lines # can be specified. A blank line marks the end of each specification. # # The Field Name in Column 10-17 designates the the Group in which the field # belongs. The First field name in a group is the Parent of the grouping # and can be used to determine how fields should be grouped. # The changing of the Parent Field marks the end of a repeating group # specification. # # Example: # # VIS_Hxxx, DVISHxxx and PVISHxxx expanded for transmission (8 and 16 hours): # # VIS_H008 # DVISH008 # PVISH008 # VIS_H016 # DVISH016 # PVISH016 # # Note: During electronic transmission, repeating field groups must be kept # together within the specified group but the order within the group # does not have to be maintained. # ########################################################################### # Start of Field Grouping Specifications # ########################################################################### # M11EGR VERSION 20020301 TST_Hxxx TST_Hxxx TST_Hxxx TEST HOURS 025 050 075 100 125 150 175 200 225 250 275 300 V100Hxxx TST_Hxxx TST_Hxxx VISCOSITY AT 100 DEG C , AT XXX HOURS 025 050 075 100 125 150 175 200 225 250 275 300 TGA_Hxxx TST_Hxxx TST_Hxxx TGA PERCENT SOOT AT XXX HOURS 025 075 100 125 150 175 200 225 275 300 TBN_Hxxx TST_Hxxx TBN_Hxxx TOTAL BASE NUMBER AT XXX HOURS 050 100 125 150 175 200 225 250 275 300 TAN_Hxxx TST_Hxxx TBN_Hxxx TAN AT XXX HOURS 050 100 125 150 175 200 225 250 275 300 CUWMHxxx TST_Hxxx TST_Hxxx CU - WEAR METALS COPPER HOURS [<] 025 050 075 100 125 150 175 200 225 250 275 300 FEWMHxxx TST_Hxxx TST_Hxxx FE - WEAR METALS IRON HOURS [<] 025 050 075 100 125 150 175 200 225 250 275 300 PBWMHxxx TST_Hxxx TST_Hxxx PB - WEAR METALS LEAD HOURS [<] 025 050 075 100 125 150 175 200 225 250 275 300 ALWMHxxx TST_Hxxx TST_Hxxx AL - WEAR METALS ALUMINUM HOURS [<] 025 050 075 100 125 150 175 200 225 250 275 300 CRWMHxxx TST_Hxxx TST_Hxxx CR - WEAR METALS CHROMIUM HOURS [<] 025 050 075 100 125 150 175 200 225 250 275 300 DOWNRxxx DOWNRxxx DOWNRxxx DOWNTIME TEST HOURS DDATRxxx DOWNRxxx DOWNRxxx DOWNTIME DATE DTIMRxxx DOWNRxxx DOWNRxxx DOWNTIME TIME DREARxxx DOWNRxxx DOWNRxxx DOWNTIME REASON OCOMRxxx OCOMRxxx OCOMRxxx OTHER DOWNTINE COMMENT XXX