########################################################################### # # # D a t a D i c t i o n a r y R e p e a t i n g # # F i e l d S p e c i f i c a t i o n s # # # ########################################################################### # The following contains specifications and field groupings for fields in the # Data Dictionary that are REPEATING Fields. These fields can be identified # in the Data Dictionary by the Hxxx or Rxxx in the last four positions of the # field name. # # Repeating fields are used to specify repeating measurements. # # The format for a repeating field name is 4 descriptive characters followed # by the letter H or R followed by 3 characters for the actual interval # the measurement was taken. The field will always be a total of 8 characters. # # Example ABCDHxxx. # # The following is the format of this specification: # # Column 1 - 8: Repeating Field Name # Column 10 - 17: The Parent Field Name of the Group # Column 19 - 26: The Measurement Interval Group Name # Column 30 - 80: Comments about the Repeating Field Group. # # The lines following the Repeating Field Name Record will contain the required # measurements for the particular field. Multiple 80 characters lines # can be specified. A blank line marks the end of each specification. # # The Field Name in Column 10-17 designates the the Group in which the field # belongs. The First field name in a group is the Parent of the grouping # and can be used to determine how fields should be grouped. # The changing of the Parent Field marks the end of a repeating group # specification. # # Example: # # VIS_Hxxx, DVISHxxx and PVISHxxx expanded for transmission (8 and 16 hours): # # VIS_H008 # DVISH008 # PVISH008 # VIS_H016 # DVISH016 # PVISH016 # # Note: During electronic transmission, repeating field groups must be kept # together within the specified group but the order within the group # does not have to be maintained. # ########################################################################### # Start of Field Grouping Specifications # ########################################################################### # IIIF VERSION 20010115 OCONHxxx OCONHxxx OCONHxxx OIL CONSUMPTION HOUR XXX (HHH) 010 020 030 040 050 060 070 080 OILLHxxx OCONHxxx OCONHxxx OIL LEVEL LOW AT XXX HOURS (ml) 010 020 030 040 050 060 070 080 NOXHHxxx NOXHHxxx NOXHHxxx NOX MEASUREMENT HOUR XXX (HHH) 007 039 079 NOX_Hxxx NOXHHxxx NOXHHxxx NOX MEASUREMENT AT XXX HOURS (ppm) 007 039 079 VISTHxxx VISTHxxx VISTHxxx VISCOSITY INCREASE HOURS XXX (HHH) 010 020 030 040 050 060 070 080 VIS_Hxxx VISTHxxx VISTHxxx VISCOSITY AT 40 DEG C AT XXX TEST HOURS (cSt) 010 020 030 040 050 060 070 080 DVISHxxx VISTHxxx VISTHxxx VISCOSITY INCREASE AT XXX HOURS (cSt) 010 020 030 040 050 060 070 080 PVISHxxx VISTHxxx VISTHxxx % VISCOSITY INCREASE @ XXX HOURS (%) 010 020 030 040 050 060 070 080 TST_Hxxx TST_Hxxx TST_Hxxx ICP ANALYSIS TEST HOURS XXX (HHH) 010 020 030 040 050 060 070 080 FEWMHxxx TST_Hxxx TST_Hxxx FE WEAR METAL AT XXX [<] (ppm) 010 020 030 040 050 060 070 080 CUWMHxxx TST_Hxxx TST_Hxxx CU WEAR METAL AT XXX [<] (ppm) 010 020 030 040 050 060 070 080 PBWMHxxx TST_Hxxx TST_Hxxx PB WEAR METAL AT XXX [<] (ppm) 010 020 030 040 050 060 070 080 BBYTHxxx BBYTHxxx BBYTHxxx TEST BLOWBY HOUR XXX (HHH) 001 006 011 016 021 026 031 036 041 046 051 056 061 066 071 076 079 BLWBHxxx BBYTHxxx BBYTHxxx TEST BLOWBY AT HOURS XXX (L/min) 001 006 011 016 021 026 031 036 041 046 051 056 061 066 071 076 079 DOWNRxxx DOWNRxxx DOWNRxxx DOWNTIME TEST HOURS (HHH:MM) DDATRxxx DOWNRxxx DOWNRxxx DOWNTIME DATE (YYYYMMDD) DTIMRxxx DOWNRxxx DOWNRxxx DOWNTIME TIME (HHH:MM) DREARxxx DOWNRxxx DOWNRxxx DOWNTIME REASON OCOMRxxx OCOMRxxx OCOMRxxx OTHER DOWNTIME COMMENT XXX