########################################################################### # # # D a t a D i c t i o n a r y R e p e a t i n g # # F i e l d S p e c i f i c a t i o n s # # # ########################################################################### # The following contains specifications and field groupings for fields in the # Data Dictionary that are REPEATING Fields. These fields can be identified # in the Data Dictionary by the Hxxx or Rxxx in the last four positions of the # field name. # # Repeating fields are used to specify repeating measurements. # # The format for a repeating field name is 4 descriptive characters followed # by the letter H or R followed by 3 characters for the actual interval # the measurement was taken. The field will always be a total of 8 characters. # # Example ABCDHxxx. # # The following is the format of this specification: # # Column 1 - 8: Repeating Field Name # Column 10 - 17: The Parent Field Name of the Group # Column 19 - 26: The Measurement Interval Group Name # Column 30 - 80: Comments about the Repeating Field Group. # # The lines following the Repeating Field Name Record will contain the required # measurements for the particular field. Multiple 80 characters lines # can be specified. A blank line marks the end of each specification. # # The Field Name in Column 10-17 designates the the Group in which the field # belongs. The First field name in a group is the Parent of the grouping # and can be used to determine how fields should be grouped. # The changing of the Parent Field marks the end of a repeating group # specification. # # Example: # # VIS_Hxxx, DVISHxxx and PVISHxxx expanded for transmission (8 and 16 hours): # # VIS_H008 # DVISH008 # PVISH008 # VIS_H016 # DVISH016 # PVISH016 # # Note: During electronic transmission, repeating field groups must be kept # together within the specified group but the order within the group # does not have to be maintained. # ########################################################################### # Start of Field Grouping Specifications # ########################################################################### # EOWT VERSION 20000602 RUN_Rxxx RUN_Rxxx RUN_Rxxx TEST RUN NUMBER EOT_Rxxx RUN_Rxxx RUN_Rxxx TEST RUN DATE COMPLETED (YYYYMMDD) POR_Rxxx RUN_Rxxx RUN_Rxxx TEST RUN PORE SIZE (micrometres) FPP_Rxxx RUN_Rxxx RUN_Rxxx TEST RUN PART/BATCH NUMBER WAT_Rxxx RUN_Rxxx RUN_Rxxx TEST RUN WATER TREAT LEVEL (%) CF1_Rxxx RUN_Rxxx RUN_Rxxx TEST RUN 20 - 25 ML CHANGE IN FLOWRATE RUN 1 (%) CF2_Rxxx RUN_Rxxx RUN_Rxxx TEST RUN 20 - 25 ML CHANGE IN FLOWRATE RUN 2 (%) CFA_Rxxx RUN_Rxxx RUN_Rxxx TEST RUN 20 - 25 ML CHANGE IN FLOWRATE AVERAGE (%) RRUNRxxx RRUNRxxx RRUNRxxx REF TEST RUN NUMBER REOTRxxx RRUNRxxx RRUNRxxx REF TEST RUN DATE COMPLETED(YYYYMMDD) RPORRxxx RRUNRxxx RRUNRxxx REF TEST RUN PORE SIZE (micrometre) RFPPRxxx RRUNRxxx RRUNRxxx REF TEST RUN PART/BATCH NUMBER RWATRxxx RRUNRxxx RRUNRxxx REF TEST RUN WATER TREAT LEVEL (%) RCF1Rxxx RRUNRxxx RRUNRxxx REF TEST RUN 20 - 25 ML CHANGE IN FLOWRATE RUN 1 (%) RCF2Rxxx RRUNRxxx RRUNRxxx REF TEST RUN 20 - 25 ML CHANGE IN FLOWRATE RUN 2 (%) RCFARxxx RRUNRxxx RRUNRxxx REF TEST RUN 20 - 25 ML CHANGE IN FLOWRATE AVERAGE (%) RINDRxxx RRUNRxxx RRUNRxxx REF TEST RUN TMC OIL CODE CMIRRxxx RRUNRxxx RRUNRxxx REF TEST RUN CMIR OCOMRxxx OCOMRxxx OCOMRxxx OTHER DOWNTIME COMMENTS XXX -n