########################################################################### # # # D a t a D i c t i o n a r y R e p e a t i n g # # F i e l d S p e c i f i c a t i o n s # # # ########################################################################### # The following contains specifications and field groupings for fields in the # Data Dictionary that are REPEATING Fields. These fields can be identified # in the Data Dictionary by the Hxxx or Rxxx in the last four positions of the # field name. # # Repeating fields are used to specify repeating measurements. # # The format for a repeating field name is 4 descriptive characters followed # by the letter H or R followed by 3 characters for the actual interval # the measurement was taken. The field will always be a total of 8 characters. # # Example ABCDHxxx. # # The following is the format of this specification: # # Column 1 - 8: Repeating Field Name # Column 10 - 17: The Parent Field Name of the Group # Column 19 - 26: The Measurement Interval Group Name # Column 30 - 80: Comments about the Repeating Field Group. # # The lines following the Repeating Field Name Record will contain the required # measurements for the particular field. Multiple 80 characters lines # can be specified. A blank line marks the end of each specification. # # The Field Name in Column 10-17 designates the the Group in which the field # belongs. The First field name in a group is the Parent of the grouping # and can be used to determine how fields should be grouped. # The changing of the Parent Field marks the end of a repeating group # specification. # # Example: # # VIS_Hxxx, DVISHxxx and PVISHxxx expanded for transmission (8 and 16 hours): # # VIS_H008 # DVISH008 # PVISH008 # VIS_H016 # DVISH016 # PVISH016 # # Note: During electronic transmission, repeating field groups must be kept # together within the specified group but the order within the group # does not have to be maintained. # ########################################################################### # Start of Field Grouping Specifications # ########################################################################### # EOEC VERSION 20040127 NVL_Rxxx NVL_Rxxx NVL_Rxxx NITRILE VOLUME CHANGE [OUTLIER] 001 002 003 004 005 006 NPH_Rxxx NVL_Rxxx NVL_Rxxx NITRILE POINTS HARDNESS CHANGE [OUTLIER] 001 002 003 004 005 006 NTS_Rxxx NVL_Rxxx NVL_Rxxx NITRILE TENSILE STRENGTH CHANGE [OUTLIER] 001 002 003 004 005 006 NEL_Rxxx NVL_Rxxx NVL_Rxxx NITRILE ELONGATION CHANGE [OUTLIER] 001 002 003 004 005 006 PVL_Rxxx PVL_Rxxx PVL_Rxxx POLYACRYLATE VOLUME CHANGE [OUTLIER] 001 002 003 004 005 006 PPH_Rxxx PVL_Rxxx PVL_Rxxx POLYACRYLATE POINTS HARDNESS CHANGE [OUTLIER] 001 002 003 004 005 006 PTS_Rxxx PVL_Rxxx PVL_Rxxx POLYACRYLATE TENSILE STRENGTH CHANGE [OUTLIER] 001 002 003 004 005 006 PEL_Rxxx PVL_Rxxx PVL_Rxxx POLYACRYLATE ELONGATION CHANGE [OUTLIER] 001 002 003 004 005 006 FVL_Rxxx FVL_Rxxx FVL_Rxxx FLUOROELASTOMER VOLUME CHANGE [OUTLIER] 001 002 003 004 005 006 FPH_Rxxx FVL_Rxxx FVL_Rxxx FLUOROELASTOMER POINTS HARDNESS CHANGE [OUTLIER] 001 002 003 004 005 006 FTS_Rxxx FVL_Rxxx FVL_Rxxx FLUOROELASTOMER TENSILE STRENGTH CHANGE [OUTLIER] 001 002 003 004 005 006 FEL_Rxxx FVL_Rxxx FVL_Rxxx FLUOROELASTOMER ELONGATION CHANGE [OUTLIER] 001 002 003 004 005 006 SVL_Rxxx SVL_Rxxx SVL_Rxxx SILICON VOLUME CHANGE [OUTLIER] 001 002 003 004 005 006 SPH_Rxxx SVL_Rxxx SVL_Rxxx SILICON POINTS HARDNESS CHANGE [OUTLIER] 001 002 003 004 005 006 STS_Rxxx SVL_Rxxx SVL_Rxxx SILICON TENSILE STRENGTH CHANGE [OUTLIER] 001 002 003 004 005 006 SEL_Rxxx SVL_Rxxx SVL_Rxxx SILICON ELONGATION CHANGE [OUTLIER] 001 002 003 004 005 006 VVL_Rxxx VVL_Rxxx VVL_Rxxx VAMAC G VOLUME CHANGE [OUTLIER] 001 002 003 004 005 006 VPH_Rxxx VVL_Rxxx VVL_Rxxx VAMAC G POINTS HARDNESS CHANGE [OUTLIER] 001 002 003 004 005 006 VTS_Rxxx VVL_Rxxx VVL_Rxxx VAMAC G TENSILE STRENGTH CHANGE [OUTLIER] 001 002 003 004 005 006 VEL_Rxxx VVL_Rxxx VVL_Rxxx VAMAC G ELONGATION CHANGE [OUTLIER] 001 002 003 004 005 006 RNVLRxxx RNVLRxxx RNVLRxxx REFERENCE NITRILE VOLUME CHANGE [OUTLIER] 001 002 003 004 005 006 RNPHRxxx RNVLRxxx RNVLRxxx REFERENCE NITRILE POINTS HARDNESS CHANGE [OUTLIER] 001 002 003 004 005 006 RNTSRxxx RNVLRxxx RNVLRxxx REFERENCE NITRILE TENSILE STRENGTH CHANGE [OUTLIER] 001 002 003 004 005 006 RNELRxxx RNVLRxxx RNVLRxxx REFERENCE NITRILE ELONGATION CHANGE [OUTLIER] 001 002 003 004 005 006 RPVLRxxx RPVLRxxx RPVLRxxx REFERENCE POLYACRYLATE VOLUME CHANGE [OUTLIER] 001 002 003 004 005 006 RPPHRxxx RPVLRxxx RPVLRxxx REFERENCE POLYACRYLATE POINTS HARDNESS CHANGE [OUTLIER] 001 002 003 004 005 006 RPTSRxxx RPVLRxxx RPVLRxxx REFERENCE POLYACRYLATE TENSILE STRENGTH CHANGE [OUTLIER] 001 002 003 004 005 006 RPELRxxx RPVLRxxx RPVLRxxx REFERENCE POLYACRYLATE ELONGATION CHANGE [OUTLIER] 001 002 003 004 005 006 RFVLRxxx RFVLRxxx RFVLRxxx REFERENCE FLUOROELASTOMER VOLUME CHANGE [OUTLIER] 001 002 003 004 005 006 RFPHRxxx RFVLRxxx RFVLRxxx REFERENCE FLUOROELASTOMER POINTS HARDNESS CHANGE [OUTLIER] 001 002 003 004 005 006 RFTSRxxx RFVLRxxx RFVLRxxx REFERENCE FLUOROELASTOMER TENSILE STRENGTH CHANGE [OUTLIER] 001 002 003 004 005 006 RFELRxxx RFVLRxxx RFVLRxxx REFERENCE FLUOROELASTOMER ELONGATION CHANGE [OUTLIER] 001 002 003 004 005 006 RSVLRxxx RSVLRxxx RSVLRxxx REFERENCE SILICON VOLUME CHANGE [OUTLIER] 001 002 003 004 005 006 RSPHRxxx RSVLRxxx RSVLRxxx REFERENCE SILICON POINTS HARDNESS CHANGE [OUTLIER] 001 002 003 004 005 006 RSTSRxxx RSVLRxxx RSVLRxxx REFERENCE SILICON TENSILE STRENGTH CHANGE [OUTLIER] 001 002 003 004 005 006 RSELRxxx RSVLRxxx RSVLRxxx REFERENCE SILICON ELONGATION CHANGE [OUTLIER] 001 002 003 004 005 006 RVVLRxxx RVVLRxxx RVVLRxxx REFERENCE VAMAC G VOLUME CHANGE [OUTLIER] 001 002 003 004 005 006 RVPHRxxx RVVLRxxx RVVLRxxx REFERENCE VAMAC G POINTS HARDNESS CHANGE [OUTLIER] 001 002 003 004 005 006 RVTSRxxx RVVLRxxx RVVLRxxx REFERENCE VAMAC G TENSILE STRENGTH CHANGE [OUTLIER] 001 002 003 004 005 006 RVELRxxx RVVLRxxx RVVLRxxx REFERENCE VAMAC G ELONGATION CHANGE [OUTLIER] 001 002 003 004 005 006 OCOMRxxx OCOMRxxx OCOMRxxx OTHER COMMENTS XXX