Version: ########################################################################### # # # R e p e a t i n g F i e l d S p e c i f i c a t i o n s # # # # 6 V 9 2 T A # # # ########################################################################### # This file contains specifications and field groupings for fields in the # Data Dictionary that are REPEATING Fields. These fields can be identified # in the Data Dictionary by the Hxxx or Rxxx in the last four positions of the # field name. # # Repeating fields are used to specify repeating measurements. # # The format for a repeating field name is 4 descriptive characters followed # by the letter H or R followed by 3 characters for the actual interval # the measurement was taken. The field will always be a total of 8 characters. # # Example ABCDHxxx. # # The following is the format of this file: # # Column 1 - 8: Repeating Field Name # Column 10 - 17: The Parent Field Name of the Group # Column 19 - 80: Comments about the Repeating Field Group. # # The lines following the Repeating Field Name Record will contain the required # measurements for the particular field. Multiple 80 characters lines # can be specified. A blank line marks the end of each specification. # # The Field Name in Column 10-17 designates the the Group in which the field # belongs. The First field name in a group is the Parent of the grouping # and can be used to determine how fields should be grouped. # The changing of the Parent Field marks the end of a repeating group # specification. # # Example: # # VIS_Hxxx, DVISHxxx and PVISHxxx expanded for transmission (8 and 16 hours): # # VIS_H008 # DVISH008 # PVISH008 # VIS_H016 # DVISH016 # PVISH016 # # Note: Repeating field groups must be kept together with in the specified # group but the order with in the group does not have to be maintained. # ########################################################################### # Start of Field Grouping Specifications # ########################################################################### # VIS_Hxxx VIS_Hxxx Viscosity Measurement Group NEW BRK 016 048 080 096 VIS1Hxxx VIS_Hxxx Viscosity Measurement Group NEW BRK 016 048 080 096 TBN_Hxxx VIS_Hxxx Viscosity Measurement Group NEW BRK 016 048 080 096 VOLTHxxx VOLTHxxx Volatility NEW 096 FE__Hxxx FE__Hxxx FE Element Group NEW BRK 016 032 048 064 080 SN__Hxxx SN__Hxxx SN Element Group NEW BRK 016 032 048 064 080 096 PB__Hxxx PB__Hxxx PB Element Group NEW BRK 016 032 048 064 080 096 CU__Hxxx CU__Hxxx CU Element Group NEW BRK 016 032 048 064 080 096 CR__Hxxx CR__Hxxx CR Element Group NEW BRK 016 032 048 064 080 096 AL__Hxxx AL__Hxxx AL Element Group NEW BRK 016 032 048 064 080 096 SI__Hxxx SI__Hxxx SI Element Group NEW BRK 016 032 048 064 080 096 CA__Hxxx CA__Hxxx CA Element Group NEW BRK 016 048 080 096 MG__Hxxx MG__Hxxx MG Element Group NEW BRK 016 048 080 096 ZN__Hxxx ZN__Hxxx ZN Element Group NEW BRK 016 048 080 096 P___Hxxx P___Hxxx P Element Group NEW BRK 016 048 080 096 MO__Hxxx MO__Hxxx MO Element Group NEW BRK 016 048 080 096 B___Hxxx B___Hxxx B Element Group NEW BRK 016 048 080 096 NA__Hxxx NA__Hxxx NA Element Group NEW BRK 016 048 080 096 S___Hxxx S___Hxxx S Element Group NEW BRK 016 048 080 096 SHOUHxxx SHOUHxxx Heat Soak Group SDATHxxx SHOUHxxx Heat Soak Group STIMHxxx SHOUHxxx Heat Soak Group SDESHxxx SHOUHxxx Heat Soak Group DOWNHxxx DOWNHxxx Down Time Occurrence Group DDATHxxx DOWNHxxx Down Time Occurrence Group DTIMHxxx DOWNHxxx Down Time Occurrence Group DREAHxxx DOWNHxxx Down Time Occurrence Group OCOMHxxx OCOMHxxx Comments and Outlier Group SCFHHxxx SCFHHxxx Area Cylinder Liner Scuffing Group SCFDHxxx SCFHHxxx Area Cylinder Liner Scuffing Group LS1LHxxx SCFHHxxx Area Cylinder Liner Scuffing Group LS2LHxxx SCFHHxxx Area Cylinder Liner Scuffing Group LS3LHxxx SCFHHxxx Area Cylinder Liner Scuffing Group LS1RHxxx SCFHHxxx Area Cylinder Liner Scuffing Group LS2RHxxx SCFHHxxx Area Cylinder Liner Scuffing Group LS3RHxxx SCFHHxxx Area Cylinder Liner Scuffing Group LSAVHxxx SCFHHxxx Area Cylinder Liner Scuffing Group ABREHxxx SCFHHxxx Area Cylinder Liner Scuffing Group PARAHxxx PARAHxxx Outlier Information Group VALUHxxx PARAHxxx Outlier Information Group TESTHxxx PARAHxxx Outlier Information Group ****************************************************************************** * * * When transmitting this Data Dictionary, a Header Data Dictionary should * * preceed the data. The latest version of this Header Data Dictionary can * * be obtained from the Test Monitoring Center either by ftp (internet) or * * by calling the Test Engineer responsible for this particular test. * * * ******************************************************************************